6.1.1 Mains phase detection
The correct polarization of mains is important for reasons of audio clarity
and stability. Please align the mains cord so that the hot pin of the wall
outlet is connected to the pin of mains input 12 marked 'PHASE' 13 on
the back panel of the unit. The ART G3 recognizes the incorrect polariza-
tion of the mains plug automatically. Right after switching on the unit
from stand-by mode by pressing the power key on the front panel the
following message will appear in the display in case the mains polariza-
tion is incorrect:
Attention:
Mains phase incorrect
If you read the above message, switch off the unit by pressing the power
key. Please wait until the display no longer reads Going to sleep...
Now pull the mains plug and re-insert it into the mains socket rotated by
180°.
When you switch on the unit again, the warning should not appear now.
Important
· If the ART G3 issues the mains polarization warning or no warning at
all for both positions of the mains plug, check the connection to earth
of your mains socket and mains cord. You have to ensure a stable
connection to earth for the ART G3 to work correctly!
6.1.2 Using Audionet Link
For your convenience, the ART G3 can be controlled remotely by one of
Audionet's pre- or integrated amplifiers using the Audionet Link inter-
face.
You only need a simple optical Toslink cable to connect the Audionet
Link output of your Audionet preamplifier to the Audionet Link input 1
of the ART G3. Now, the ART G3 and all other units connected via
Audionet Link will be switched on/off automatically, when you switch
on/off your preamplifier at the front panel or by remote control (refer to
section 'Audionet Link' on page 21).
If your ART G3 is connected to your Audionet preamplifier via Audionet
Link, the ART G3 will be switched on/off automatically, as soon as you
switch on/off your Audionet preamplifier with its remote control or with
the power key on its front panel.
Note
· The 'switch on' signal is issued to any further Audionet units daisy
chained to the Audionet Link output of your ART G3 with a little de-
lay to avoid all units switching on at the same moment, which could
cause an overload of your mains fuse. First, control output Audionet
Link OUT 1 2 , then Audionet Link OUT 2 3 is activated.