In order to set the system address you first have to open up the remote
control (see section 'Changing the batteries' on page 30). The DIP switch
for selecting the system address is located here:
Put the DIP switch labelled 'SYS ADDRESS' in position '19' or '16' ac-
cording to the following table:
Audionet preamplifier Address
PRE G2, PRE 1 G3,
SAM G2,
DNA, DNP, DNA 1
19
MAP 1 16
Note
· If not ordered explicitly, the Audionet Metall Remote Control is pre-
configured to setting '19' of the DIP switch.
· Older models of Audionet preamplifiers use system address 16.
Tip
· If you own an Audionet preamplifier that is not listed in the table
above and/or you don't know which system address it uses, then sim-
ply try out both settings.
DIP switch for system address